Pressure plate for tension anchor HTA
Tension anchor plate, HTA
TENSANCPLT-F.AIRTGT-HTA-58,5X50X10MM
Art.-no.
5392000105
EAN 4053479327334
Price for selected packaging unit

Exclusively for trade customers
Register now and access more than 125,000 products
To increase the tension resistance of tension anchor HTA
- Steel plate galvanised on all sides (S355 MC + Fe Zn 12c) as per EN 10025-2:2004
- Application in utilisation classes 1 and 2 in line with EN 1995:2013
Proof of Performance
CE labelling as per European Technical Approval ETA-14/0274
Notes: |
Würth anchor nails or ASSY 3.0 joist hanger screws according to EN 14592 or ETA 11/0190 are to be used as fasteners. The specified load-bearing capacities are for softwood with a characteristic density of ρk ≥ 350 kg/m³. Design value of the load-bearing capacity of a fastener: FVM,Rd = kmod/gM = F1,Rk with gM = 1.3 Design value of the steel load-bearing capacity of the tension anchor: FS,Rd = FS,Rk/gM2 with gM2 = 1.25 Design value of the total load-bearing capacity: F1,Rd = min {n x FVM,Rd; FS,Rd} with n = number of nails The design value of the tensile force in the anchor bolt FB,Ed is to be calculated with the design value of the tensile force of a tension anchor FEd. The minimum distances between fasteners for sheet steel-wood connections according to EN 1995-1-1 must be observed. The specified values given were calculated on the assumption of an immovable intermediate layer according to Blass and Laskewitz "Load-bearing capacity of connections with pin-shaped fasteners and intermediate layers". |
Product information
Datasheets(X)
Application area
For increasing the tension resistance of tension anchor HTA for anchoring supports, roof beams, timber frame constructions or solid wood elements.
![]() | |
Length x width x height | 58.5 x 50 x 10 mm |
Diameter of hole | 17 mm |
Number of holes | 1 PCS |
Weight | 200 g |
Surface | Zinc plated |
Material | Steel / steel |
Material standard | EN 10025- 2:2004 |
Approval | ETA-14/0274 |
Required number of fasteners for HTA Lx80x80x3.0 depending on the connection of tensile load FEd to softwood C24 | ||||||||||
FEd in kN | Würth anchor nail in mm Load-bearing capacity class 3 4x40 4x50 4x60 4x75 4x100 | ASSY 3.0 joist hanger screw in mm ETA-11/0190 5x35 5x40 5x50 5x60 5x70 | ||||||||
4 | 4 | 4 | 3 | 3 | 3 | 4 | 3 | 3 | 3 | 3 |
5 | 5 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 3 | 3 |
6 | 6 | 5 | 5 | 5 | 5 | 5 | 5 | 4 | 4 | 4 |
7 | 7 | 6 | 6 | 5 | 5 | 6 | 5 | 5 | 5 | 4 |
8 | 8 | 7 | 6 | 6 | 6 | 7 | 6 | 6 | 5 | 5 |
9 | 9 | 7 | 7 | 7 | 7 | 7 | 7 | 6 | 6 | 6 |
10 | 10 | 8 | 8 | 8 | 8 | 8 | 7 | 7 | 6 | 6 |
Calculation of the load-bearing capacities of fasteners according to DIN EN 1995-1-1 as for thick steel sheets. The required minimum distances between the fasteners must be observed! The specifications are valid for a characteristic density ρk = 350 kg/m³ and for kmod = 0.9. |
Characteristic load-bearing capacity and design value of the load-bearing capacity ("short") in load case F1 for Würth tension anchor HTA according to ETA 14/0274 | ||||||||||||
Type | Format in mm | U-washer/base plate | KLED | Load-bearing capacity per fastener (anchor nail or joist hanger screw in mm) in kN | Load-bearing capacity steel in kN | Coefficient kt | ||||||
HTA | 4x40 | 4x50 | 4x60 | 5x35 | 5x40 | 5x50 | ||||||
Lx60x60x3.0 | U-washer 30x3 mm | char. | FVM,Rk = | 1,59 | 1,87 | 1,93 | 1,88 | 2,10 | 2,29 | FS,Rk =35.0 | 3,79 | |
Short | FVM,Rd = | 1,10 | 1,30 | 1,34 | 1,30 | 1,46 | 1,59 | FS,Rd =28.0 | ||||
Lx60x60x3.0 | Base plate 10 mm | char. | FVM,Rk = | 1,59 | 1,87 | 1,93 | 1,88 | 2,10 | 2,29 | FS,Rk =45.0 | 3,79 | |
Short | FVM,Rd = | 1,10 | 1,30 | 1,34 | 1,30 | 1,46 | 1,59 | FS,Rd =36.0 | ||||
Tensile force in anchor bolt: FB,Ed = kt x FEd |
Tension anchor connection - softwood C24 with 16 mm chipboard as intermediate layer | ||||||||||||
Type | Format in mm | U-washer/base plate | KLED | Load-bearing capacity per fastener (anchor nail or joist hanger screw in mm) in kN | Load-bearing capacity Steel in kN | Coefficient kt | ||||||
4x40 | 4x50 | 4x60 | 5x35 | 5x40 | 5x50 | |||||||
HTA | Lx60x60x3.0 | U-washer 30x3 mm | char. | FVM,Rk = | 1,97 | 2,06 | 2,15 | 2,03 | 2,18 | 2,33 | FS,Rk =35.0 | 3,79 |
Short | FVM,Rd = | 1,37 | 1,43 | 1,49 | 1,40 | 1,51 | 1,61 | FS,Rd =28.0 | ||||
Lx60x60x3.0 | Base plate 10 mm | char. | FVM,Rk = | 1,97 | 2,06 | 2,15 | 2,03 | 2,18 | 2,33 | FS,Rk =45.0 | 3,79 | |
Short | FVM,Rd = | 1,37 | 1,43 | 1,49 | 1,40 | 1,51 | 1,61 | FS,Rd =36.0 | ||||
Tensile force in anchor bolt: FB,Ed = kt x FEd |
Tension anchor connection - softwood C24 with 15 mm OSB as intermediate layer | ||||||||||||
Type | Format in mm | U-washer/base plate | KLED | Load-bearing capacity per fastener (anchor nail or joist hanger screw in mm) in kN | Load-bearing capacity Steel in kN | Coefficient kt | ||||||
4x40 | 4x50 | 4x60 | 5x35 | 5x40 | 5x50 | |||||||
HTA | Lx60x60x3.0 | U-washer 30x3 mm | char. | FVM,Rk = | 2,03 | 2,09 | 2,18 | 2,08 | 2,23 | 2,38 | FS,Rk =35.0 | 3,79 |
Short | FVM,Rd = | 1,41 | 1,45 | 1,51 | 1,44 | 1,54 | 1,65 | FS,Rd =28.0 | ||||
Lx60x60x3.0 | Base plate 10 mm | char. | FVM,Rk = | 2,03 | 2,09 | 2,18 | 2,08 | 2,23 | 2,38 | FS,Rk =45.0 | 3,79 | |
Short | FVM,Rd = | 1,41 | 1,45 | 1,51 | 1,44 | 1,54 | 1,65 | FS,Rd =36.0 | ||||
Tensile force in anchor bolt: FB,Ed = kt x FEd |